The short answer
H7 is a standard tolerance class for holes in the ISO system of limits and fits (ISO 286). It means two things:
- “H”: the hole’s smallest allowed size is exactly the nominal size. It can never be undersize.
- “7”: the hole may be larger than nominal by an amount set by tolerance grade IT7, which depends on the hole’s diameter.
For example, a 10 mm H7 hole must measure between 10.000 mm and 10.015 mm. H7 is one of the most widely used hole tolerances in mechanical design, especially for holes that take pins, shafts and bearings.
Reading the code: the letter and the number
ISO 286 tolerance codes have two parts: a letter (or letters) and a number.
The “H” (fundamental deviation)
The letter sets where the tolerance band sits relative to the nominal size. For holes, the letter “H” places the lower limit exactly on the nominal size, so the lower deviation is zero. Other letters shift the band: for instance, letters earlier in the alphabet put the band further above nominal (making looser holes), while letters later in the alphabet put it closer to or below nominal.
The “7” (IT grade)
The number is the International Tolerance (IT) grade. It sets how wide the tolerance band is. Lower numbers mean a narrower band and tighter tolerance; higher numbers mean a wider band. The width also grows with the size of the feature, because bigger features are harder to make precisely. IT7 is a fairly precise grade that good machining processes such as reaming or fine boring can achieve.
Capital letters vs lowercase
In ISO 286, capital letters are used for holes (H7, G7, F8) and lowercase letters for shafts (h6, g6, k6, p6). So “H7” always refers to a hole and “h7” to a shaft. Mixing these up on a drawing changes the meaning entirely.
H7 values for common sizes
Because the “H” lower deviation is zero, the H7 upper deviation equals the IT7 band width for that size range. Values in micrometers (µm), where 1 µm = 0.001 mm:
| Nominal size (mm) | Lower deviation | Upper deviation |
|---|---|---|
| Over 1 up to 3 | 0 | +10 µm |
| Over 3 up to 6 | 0 | +12 µm |
| Over 6 up to 10 | 0 | +15 µm |
| Over 10 up to 18 | 0 | +18 µm |
| Over 18 up to 30 | 0 | +21 µm |
| Over 30 up to 50 | 0 | +25 µm |
| Over 50 up to 80 | 0 | +30 µm |
| Over 80 up to 120 | 0 | +35 µm |
Size ranges include the upper value, so a 10 mm hole falls in the “over 6 up to 10” row. For larger sizes or official use, check a full ISO 286-2 table or a trusted engineering reference.
Worked example: a 10 mm H7 hole
A drawing shows “Ø10 H7”.
- Find the row: 10 mm falls in “over 6 up to 10”.
- Lower deviation: 0, so the minimum size is 10.000 mm.
- Upper deviation: +15 µm (+0.015 mm), so the maximum size is 10.015 mm.
The hole must measure between 10.000 mm and 10.015 mm. That total band of 0.015 mm is much tighter than a typical general tolerance such as ±0.1 mm, which is why H7 holes need suitable tooling and careful measurement.
H7 in fits
H7 is most often used as part of a fit, written as hole class over shaft class, such as H7/g6. The shaft tolerance class decides what kind of fit you get. Some commonly used combinations from the ISO preferred fits:
| Fit | Type | Typical use |
|---|---|---|
| H7/g6 | Close clearance (sliding) | Parts that slide or turn with little play, such as precise guides |
| H7/h6 | Locational clearance | Parts that locate accurately but can still be assembled and removed by hand |
| H7/k6 | Locational transition | Accurate location where a slight interference is acceptable |
| H7/p6 | Locational interference | Parts pressed together that should stay put, such as some bushings and dowels |
These descriptions are general. Bearing manufacturers, for example, publish their own recommended shaft and housing tolerances, so follow the component supplier’s guidance where it exists.
The hole-basis system
Using an “H” hole and varying the shaft to get different fits is called the hole-basis system. It is popular because holes are usually made with fixed-size tools such as reamers, and it is easier and cheaper to keep a small set of H7 reamers and adjust the shaft (which can be turned or ground to any size) than the other way around. There is also a shaft-basis system built on “h” shafts, used where a standard shaft size, such as ground bar stock, is the starting point.
How H7 holes are made
A plain twist drill typically won’t reliably produce an H7 hole. Common methods include:
- Drill then ream: drill slightly undersize, then finish with an H7 reamer. This is very common for dowel pin holes.
- Boring: on a lathe or mill, a boring bar can bring a hole to size accurately, especially for larger diameters.
- Honing or grinding: used where very fine finish and accuracy are needed.
Checking is usually done with a go/no-go plug gauge, a bore gauge or a coordinate measuring machine (CMM), since calipers are generally not precise enough to confirm a 0.015 mm band.
For 3D-printed or molded prototypes, H7 is generally not achievable straight off the machine. If a prototype needs an accurate bore, a common approach is to print or mold slightly undersize and ream to finish.
Using H7 in product design and CAD
- Call it out on the drawing next to the diameter, such as “Ø8 H7”. Many CAD programs let you pick ISO fits from a list and will add the limit values for you.
- Use it only where needed. Holes for bolts usually need a clearance hole with a loose tolerance, not H7. Save H7 for pins, shafts, bearings and precise locating features.
- Pair it with the right shaft class to get the fit you want.
- Check with your supplier that they have the tooling and inspection setup for the sizes you specify.
H7 is just one piece of a larger topic. For how size tolerances, fits, GD&T and stack-ups fit together, see our guide to tolerance in product design.